Friday, September 30, 2011

Sterilization

Sterilization
Any instrument which is placed in the root canal should be sterile, for two reasons. Firstly, to prevent the introduction to the root canal system of extraneous microorganisms, which may severely compromise treatment, for example pseudomonas.
Secondly, if instruments and devices were to be used on different patients, to prevent cross-infection between patients. Bacteria, viruses, fungi and prions may contaminate instruments and research has shown that some of these may not be destroyed by any method of sterilization.
Figure 18 illustrates this dramatically. Concern has been raised over the sterilization of other items of dental equipment as well.

Measurement of working length

There are two established methods of assessing the working length of a root canal: one by radiography and the other with the use of an electronic device apex locator (Fig. 16). 

Once the working length has been confirmed, the individual preparation instruments must be accurately marked to length accordingly. There are many different gadgets available for transfer of the working length; the author prefers the device shown in Figure 17. There are also different stops for the instrument, the most popular being rubber or silicone stops. These should always be placed at right angles to the shank of the instrument. Ideally the stops should be either notched, or pear shaped, so that in curved canals the notch or point of the pear may be directed towards the curve placed in the instrument. 
Measurement of working length

Both methods will be described in Part 7.
Once the working length has been confirmed, the individual preparation instruments must be accurately marked to length accordingly. There are many different gadgets available for transfer of the working length; the author prefers the device shown in Figure 17. There are also different stops for the instrument, the most popular being rubber or silicone stops. These should always be placed at right angles to the shank of the instrument. Ideally the stops should be either notched, or pear shaped, so that in curved canals the notch or point of the pear may be directed towards the curve placed in the instrument.

Thursday, September 29, 2011

Burs

Burs

Several types of bur may be required for root canal treatment. Some of these are described below, and shown in Figure 14.
Cutting an access cavity
It is generally accepted that high speed burs should be used to gain access and shape the cavity. A diamond or tungsten carbide tapered fissure bur is used for initial penetration of the roof of the pulp chamber. A tapered safe-ended diamond or tungsten carbide bur is then used to remove the roof of the pulp chamber without damaging the floor. 
Location of canal
Burs should only be used as a last resort to locate a sclerosed canal because of the danger of perforation. Small round burs are used; the standard length is usually too short but longer shank burs are available. Specially designed ultrasonic tips may also be used to remove secondary dentine, assist in the identification of canal orifices and in shaping the canal orifice during preparation. The use of ultrasonic tips has become more widespread with the introduction of a wider range of fittings to different piezo-electronic machines. Figure 15 shows the diamond coated CPRfi tips, designed for troughing and chasing sclerosed canals, and the BUCfi tips, with variable grades of diamond grit for refining access cavity walls and line angles, removing obstructions and cutting around posts. As with all instruments and materials, the manufacturer s instructions and guidance should be carefully followed or these delicate diamond tips may be damaged. It is generally wise to use them with a low power setting, and to ensure that they are in contact with dentine before activating the piezoelectric unit.
Canal preparation
The use of rotary cutting instruments in a standard handpiece is condemned because of the danger of fracture of the instrument or perforation of the root canal. The exception to this rule is the Gates Glidden bur, which has a safeended tip. In addition, the site of fracture, if it does occur, is almost always near the hub so the fractured piece is easily removed. In the past this bur has been recommended for initial flaring of the coronal portion of the canal. This may now be carried out in a more controlled manner with a nickel-titanium orifice shaper. The Gates  Glidden bur may also be used to make post space and to remove gutta-percha from the canal. Gates Glidden burs are manufactured in six sizes; their use is described in Part 7